Commercial steel pipeline

Water at 180°F is to be pumped through a long schedule 40, 3-in. commercial steel pipeline. At steady-state operation, a Goulds 2 X 3-13 pump (Fig. 4-18) is operating at 180 gpm and 152 ft-lbf/lbm head. The pressure at the inlet to the pipeline is 14.7 psia. Find the pump placement required to prevent cavitation […]

Commercial steel pipeline Read More »

Wind tunnel

The wind tunnel in the Mississippi State University Thermal and Fluid Dynamics Laboratory has a cooling water loop which is used to control the tunnel operating temperature. The loop is shown in Fig. P4-13. The water temperature is controlled by continuously dumping hot water and mixing in cool water from the plant water system. The

Wind tunnel Read More »

The pump’s location

For the system shown in Fig.P4-14, a Goulds 2 X 3-13 (Fig.4-18) with a 12-in.rotor is used to pump 250 gpm from the lower to the upper reservoir. The liquid being pumped is water at 175°F. (a) Neglecting friction, what restrictions are there on the pump’s location? (b) If friction were considered, would it increase

The pump’s location Read More »

Same system characteristic

Several Goulds 2 X 3-10 (A60) pumps (Fig. 4-16) are used in series and parallel pumping arrangements. In one series arrangement (system characteristic H = 0.146Q2) and one parallel arrangement (system characteristic H = 0.00032Q2) there are two pumps with 10-in. rotors, both at 1,750 rpm. In another series arrangement and another parallel arrangement (same

Same system characteristic Read More »

Pump operating point

Hot water, initially at 200°F and 14.7 psia, is piped through a series system that is 1,000 ft long and contains 12 elbows, a heat exchanger, and a plug disk glove valve. Schedule 40 pipe of 3-in. nominal diameter is used. The head loss across the heat exchanger is = 2388.7~, where Q [==] ft3

Pump operating point Read More »

The system capability

Water at 180°F is to be pumped through a long schedule 40,3-in. commercial steel pipeline. At steady-state operation, a Goulds 2 X 3-10 pump (Fig. 4-16) is operating at 306 gpm and 260 ft-lbf/Ibm head. The pipeline inlet is to a shallow reservoir. Find the angle of the pipeline at which pump placement due to

The system capability Read More »

Priorities of the current/sitting U.S. president

Review the agenda priorities of the current/sitting U.S. president and the two previous presidentialadministrations.Select an issue related to healthcare that was addressed by each of the last three U.S. presidentialadministrations.Reflect on the focus of their respective agendas, including the allocation of financial resources for addressingthe healthcare issue you selected.Consider how you would communicate the importance